| Unit weight of reinforced concrete | 25 | kN/m³ | SIA 261:2020, Annex A, Table 28 | taken from SIASIA 261:2020, Annex A, Table 28 |
| Unit weight of asphalt surfacing | 24 | kN/m³ | SIA 261:2020, Annex A, Table 28 | taken from SIASIA 261:2020, Annex A, Table 28 |
| Characteristic compressive strength, C50/60 | 50 | MPa | SIA 262:2013, Table 3 | taken from SIASIA 262:2013, Table 3 |
| Offset fcm − fck | 8 | MPa | SIA 262:2013, 3.1.2.2.2, eq. (6). fcm = 58 MPa for C50/60, as in Table 3 | taken from SIASIA 262:2013, 3.1.2.2.2, eq. (6) |
| Coefficient kE of Ecm = kE ∛fcm (MPa) | 10,000 | | SIA 262:2013, 3.1.2.3.3, eq. (10). Low end of the 10,000 to 12,000 range for alluvial gravel: a cautious choice for deflections | taken from SIASIA 262:2013, 3.1.2.3.3, eq. (10) |
| Mean tensile strength fctm, C50/60 | 4.1 | MPa | SIA 262:2013, Table 3. Tabulated value (the former formula 0.30 fck^(2/3) came from EN 1992-1-1) | taken from SIASIA 262:2013, Table 3 |
| Partial factor for concrete γc | 1.5 | | SIA 262:2013, 2.3.2.6. fcd = ηfc ηt fck / γc, eq. (2) | taken from SIASIA 262:2013, 2.3.2.6 |
| Load duration factor ηt, general case | 1 | | SIA 262:2013, 4.2.1.3. ηt = 1.0 if the share of permanent loads in the design effect does not exceed 90 % | taken from SIASIA 262:2013, 4.2.1.3 |
| Load duration factor ηt, permanent loads predominant | 0.85 | | SIA 262:2013, 4.2.1.3. Applied point by point (deck and pylon) where the permanent share of the ULS effect exceeds the threshold below | taken from SIASIA 262:2013, 4.2.1.3 |
| Threshold of the permanent load share in the design effect for ηt = 0.85 | 0.9 | | SIA 262:2013, 4.2.1.3. Permanent share = (γG G + γP P) / (γG G + γP P + γQ Q) at each checked point, ULS effects of V8 and V9 | taken from SIASIA 262:2013, 4.2.1.3 |
| Reference of ηfc = ∛(30 / fck) ≤ 1 | 30 | MPa | SIA 262:2013, 4.2.1.2, eq. (26) | taken from SIASIA 262:2013, 4.2.1.2, eq. (26) |
| Maximum concrete compression during tensioning and just after, outside anchorage zones | 0.6 | × fck(t) | SIA 262:2013, 4.1.5.2.4, eq. (23). Check V13 | taken from SIASIA 262:2013, 4.1.5.2.4, eq. (23) |
| Minimum fck(t) at the time of tensioning | 0.3 | × fck | SIA 262:2013, 4.1.5.2.4 | taken from SIASIA 262:2013, 4.1.5.2.4 |
| Non-linear creep threshold: above it, φ is multiplied by βσc = e^(1.5 (σc / fck − 0.45)) | 0.45 | × fck | SIA 262:2013, 3.1.2.6.3, eq. (14). Indicator shown with V2 (quasi-permanent combination) | taken from SIASIA 262:2013, 3.1.2.6.3, eq. (14) |
| SLS characteristic (rare) compression limit: k1 fck (V1) | 0.6 | × fck | Design choice, not an SIA requirement: SIA 262 limits concrete compression only at tensioning (4.1.5.2.4). EN 1992-1-1 7.2(2) criterion, k1 = 0.6 (classes XD, XF, XS: longitudinal cracks) | design choice |
| SLS quasi-permanent compression limit: k2 fck (V2, linear creep) | 0.45 | × fck | Design choice, not an SIA requirement: keep creep linear. EN 1992-1-1 7.2(3), k2 = 0.45. In SIA 262, 0.45 fck is the βσc threshold (3.1.2.6.3), not a limit | design choice |
| SLS characteristic (rare) tensile limit (V3, uncracked section, model assumption) | 1 | × fctm | Design choice, not an SIA requirement: keeps the uncracked linear analysis valid. Transition to the cracked state at fctm per SIA 262 4.2.1.14; EN 1992-1-1 7.1(2). Must stay > 0 (otherwise V4 is the check) | design choice |
| Decompression under SLS frequent: σ ≤ 0 at both fibres (V4) | 0 | MPa | Design choice, not an SIA requirement: SIA 262 has no decompression criterion. EN 1992-2 7.3.1, Table 7.101N (bonded tendons, classes XD, XS) | design choice |
| Cracking requirements | accrues | | SIA 262:2013, 4.4.2.2.5 (increased requirements, set in the basis of design per 4.4.2.2.2). Checked on the reinforcement (Table 17, Figure 31; frequent combination Δσs ≤ fsd − 80 MPa), outside the model | project assumption |
| Area of one Y1860S7-15.7 strand | 150 | mm² | SIA 262:2013, Table 7 | taken from SIASIA 262:2013, Table 7 |
| Strand tensile strength | 1,860 | MPa | SIA 262:2013, 3.3.2.2, Table 7 | taken from SIASIA 262:2013, 3.3.2.2, Table 7 |
| 0.1 % proof stress fp0.1k | 1,600 | MPa | SIA 262:2013, Table 7. The former value 1,640 MPa came from EN 10138-3 | taken from SIASIA 262:2013, Table 7 |
| Strand elastic modulus | 195 | GPa | SIA 262:2013, 3.3.2.4.2 | taken from SIASIA 262:2013, 3.3.2.4.2 |
| Partial factor for prestressing steel γs (fpd = fp0.1k / γs) | 1.15 | | SIA 262:2013, 2.3.2.6; eq. (5) in 2.3.2.5. fpd = 1,390 MPa in Table 10. Also applied to the stays as an assumption: SIA 262 does not cover stays; rules specific to stays (EN 1993-1-11 section 6, fib Bulletin 30) give a lower design resistance, about 0.70 to 0.75 fpk | taken from SIASIA 262:2013, 2.3.2.6; eq. (5) in 2.3.2.5 |
| Stay stress limit at SLS characteristic (rare) (V5) | 0.45 | × fpk | Project assumption, usual practice: SIA sets no limit for stays. fib Bulletin 30, CIP / Sétra 2001 recommendations, EN 1993-1-11 section 7 | project assumption |
| Maximum jacking stress of the internal prestress, during tensioning | 0.75 | × fpk | SIA 262:2013, 4.1.5.2.1, eq. (21). Limit of the jacking stress (stress adopted: kSigmaVerin); the former second term 0.9 fp0.1k came from EN 1992-1-1 | taken from SIASIA 262:2013, 4.1.5.2.1, eq. (21) |
| Maximum prestressing steel stress just after tensioning (V14) | 0.7 | × fpk | SIA 262:2013, 4.1.5.2.2, eq. (22) | taken from SIASIA 262:2013, 4.1.5.2.2, eq. (22) |
| Minimum prestressing steel stress after all losses (V15) | 0.45 | × fpk | SIA 262:2013, 4.1.5.2.3 | taken from SIASIA 262:2013, 4.1.5.2.3 |
| Tandem axle load, lane 1 | 300 | kN | SIA 261:2020, 10.2.2.2, Table 10 | taken from SIASIA 261:2020, 10.2.2.2, Table 10 |
| Tandem axle load, lane 2 | 200 | kN | SIA 261:2020, 10.2.2.2, Table 10. Tandems of lanes 1 and 2 in the same section (10.2.2.3) | taken from SIASIA 261:2020, 10.2.2.2, Table 10 |
| Uniformly distributed load, lane 1 | 9 | kN/m² | SIA 261:2020, 10.2.2.5, Table 10 | taken from SIASIA 261:2020, 10.2.2.5, Table 10 |
| Uniformly distributed load, lane 2 | 2.5 | kN/m² | SIA 261:2020, 10.2.2.5, Table 10 | taken from SIASIA 261:2020, 10.2.2.5, Table 10 |
| Uniformly distributed load, remaining area | 2.5 | kN/m² | SIA 261:2020, 10.2.2.6, Table 10 | taken from SIASIA 261:2020, 10.2.2.6, Table 10 |
| Coefficient αQ1 | 0.9 | | SIA 261:2020, 10.3.2. Normal case; the 10.3.3 reduction does not apply (2 carriageways) | taken from SIASIA 261:2020, 10.3.2 |
| Coefficient αQ2 | 0.9 | | SIA 261:2020, 10.3.2 | taken from SIASIA 261:2020, 10.3.2 |
| Coefficient αq1 | 0.9 | | SIA 261:2020, 10.3.2. The former value 0.5 does not exist in SIA 261:2020 | taken from SIASIA 261:2020, 10.3.2 |
| Coefficient αqi (i ≥ 2) | 0.9 | | SIA 261:2020, 10.3.2. The former value 1.0 was the EN 1991-2 one | taken from SIASIA 261:2020, 10.3.2 |
| Coefficient αqr (remaining area) | 0.9 | | SIA 261:2020, 10.3.2. The former value 1.0 was the EN 1991-2 one | taken from SIASIA 261:2020, 10.3.2 |
| Notional lane width | 3 | m | SIA 261:2020, 10.2.1.1, Table 9. Carriageway narrower than 5.4 m: 1 lane of 3 m and a remaining area | taken from SIASIA 261:2020, 10.2.1.1, Table 9 |
| Spacing of the 2 tandem axles | 1.2 | m | SIA 261:2020, 10.2.2.2, Figure 11 | taken from SIASIA 261:2020, 10.2.2.2, Figure 11 |
| Braking: axle load coefficient, QBk = 1.2 αQ1 Qk1 + 0.1 αq1 qk1 b1 l | 1.2 | | SIA 261:2020, 10.2.4.2, eq. (20) | taken from SIASIA 261:2020, 10.2.4.2, eq. (20) |
| Braking: distributed load coefficient (b1 = lane 1 width, l = 280 m between joints) | 0.1 | | SIA 261:2020, 10.2.4.2, eq. (20) | taken from SIASIA 261:2020, 10.2.4.2, eq. (20) |
| Braking: maximum value of QBk | 900 | kN | SIA 261:2020, 10.2.4.2. Acts with load model 1 (10.2.6.1), at carriageway level (10.2.4.1) | taken from SIASIA 261:2020, 10.2.4.2 |
| Dynamic factor on axle loads up to 3 m from an expansion joint (not applied: local effect, outside the model) | 1.3 | | SIA 261:2020, 10.3.4. Concerns abutment reactions, the joint and the slab near the abutments, not the global forces | taken from SIASIA 261:2020, 10.3.4 |
| Load factor, permanent actions, unfavourable γG,sup | 1.35 | | SIA 260:2013, Table 1, limit state type 2 | taken from SIASIA 260:2013, Table 1, limit state type 2 |
| Load factor, permanent actions, favourable γG,inf | 0.8 | | SIA 260:2013, Table 1, limit state type 2. Note 1 of the table: choice of γG,sup or γG,inf | taken from SIASIA 260:2013, Table 1, limit state type 2 |
| Load factor for prestressing γP (on Pk, mean value after losses) | 1 | | Project assumption, usual Swiss practice: Pk = mean value (SIA 260:2013, 3.2.2.5), γP per SIA 260:2013, 4.4.3.4, which refers to SIA 262. SIA 262 gives γP only for prestress introduction and anchorage zones (4.1.5.5.2) | project assumption |
| Load factor for road traffic γQ (load model 1 and braking) | 1.5 | | SIA 260:2013, Table 1, limit state type 2 | taken from SIASIA 260:2013, Table 1, limit state type 2 |
| ψ0 of load model 1 (combination value), when temperature is the leading action | 0.75 | | SIA 260:2013, Annex B, Table 6. Road bridges, load model 1 | taken from SIASIA 260:2013, Annex B, Table 6 |
| ψ1 of the tandem system (frequent) | 0.75 | | SIA 260:2013, Annex B, Table 6. Road bridges, load model 1 (same value for the whole model) | taken from SIASIA 260:2013, Annex B, Table 6 |
| ψ1 of the distributed load (frequent) | 0.75 | | SIA 260:2013, Annex B, Table 6. Road bridges, load model 1 (same value for the whole model) | taken from SIASIA 260:2013, Annex B, Table 6 |
| ψ2 of the tandem system (quasi-permanent) | 0 | | SIA 260:2013, Annex B, Table 6 | taken from SIASIA 260:2013, Annex B, Table 6 |
| ψ2 of the distributed load (quasi-permanent) | 0 | | SIA 260:2013, Annex B, Table 6 | taken from SIASIA 260:2013, Annex B, Table 6 |
| ψ1 of the traffic horizontal forces (braking, frequent) | 0.75 | | SIA 260:2013, Annex B, Table 6. Road bridges, horizontal forces | taken from SIASIA 260:2013, Annex B, Table 6 |
| ψ0 of the traffic horizontal forces (braking), when temperature is the leading action | 0.75 | | SIA 260:2013, Annex B, Table 6. Road bridges, horizontal forces | taken from SIASIA 260:2013, Annex B, Table 6 |
| ψ2 of the traffic horizontal forces (quasi-permanent) | 0 | | SIA 260:2013, Annex B, Table 6 | taken from SIASIA 260:2013, Annex B, Table 6 |
| ψ0 of temperature effects (rare, ULS) | 0.6 | | SIA 260:2013, Annex B, Table 6. Road bridges, temperature effects | taken from SIASIA 260:2013, Annex B, Table 6 |
| ψ1 of temperature effects (frequent, temperature leading) | 0.6 | | SIA 260:2013, Annex B, Table 6 | taken from SIASIA 260:2013, Annex B, Table 6 |
| ψ2 of temperature effects (quasi-permanent, and frequent with traffic leading) | 0.5 | | SIA 260:2013, Annex B, Table 6 | taken from SIASIA 260:2013, Annex B, Table 6 |
| Coefficient of thermal expansion of concrete and steel | 10 | 10⁻⁶/°C | SIA 261:2020, 7.1.5, Table 5 | taken from SIASIA 261:2020, 7.1.5, Table 5 |
| Uniform temperature change, prestressed concrete (deck and pylon) | 20 | ± °C | SIA 261:2020, 7.2.4, Table 6. Deck sliding at the abutments: only the elongation of the pylon below the deck (20 m) creates forces | taken from SIASIA 261:2020, 7.2.4, Table 6 |
| Uniform temperature change, steel (stays) | 30 | ± °C | SIA 261:2020, 7.2.4, Table 6 | taken from SIASIA 261:2020, 7.2.4, Table 6 |
| Section depths of the two table rows (linear interpolation between them) | 1; 3 | m | SIA 261:2020, 7.2.5, Table 7, note 1 | taken from SIASIA 261:2020, 7.2.5, Table 7, note 1 |
| Linear part T2k, top face warmer, concrete bridge, at the two depths | 12; 8 | °C | SIA 261:2020, 7.2.5, Table 7. Interpolated for h = 2.5 m | taken from SIASIA 261:2020, 7.2.5, Table 7 |
| Linear part T2k, top face cooler, concrete bridge, at the two depths | −4; −3 | °C | SIA 261:2020, 7.2.5, Table 7. Interpolated for h = 2.5 m | taken from SIASIA 261:2020, 7.2.5, Table 7 |
| Comfort: minimum ratio l / w, w = deflection under the frequent value of load model 1 (frequent load case) | 500 | | SIA 260:2013, Annex B, Table 7. Comfort row, note 4 (indicative value) | taken from SIASIA 260:2013, Annex B, Table 7 |
| Appearance: minimum ratio l / w, w = deflection under the quasi-permanent load case, precamber deducted | 700 | | SIA 260:2013, Annex B, Table 7. Appearance row, notes 1 and 2 (indicative value) | taken from SIASIA 260:2013, Annex B, Table 7 |
| Carriageway joint at the abutments: maximum relative vertical displacement between the deck end and the abutment, frequent load case | 5 | mm | SIA 260:2013, Annex B, Table 7. Carriageway transition joint row, frequent (21) column, notes 1 to 3 (indicative value) | taken from SIASIA 260:2013, Annex B, Table 7 |
| Minimum critical factor (model check) for amplifying first order by 1 / (1 − 1 / αcr) | 3 | | Project assumption, model check criterion, not SIA: EN 1993-1-1 5.2.2(5)B practice. SIA 262 checks second order on the deformed system (4.3.7) | project assumption |