All projects

Engineering project · Calculation method

Cable-stayed bridge: calculation method

The bridge on the home page is computed in your browser. Here are the model, its assumptions, its equations and how I checked it.

spans
2 × 140 m
model
217 degrees of freedom
SIA values
taken from SIA 260, 261 and 262

The project

A 280 m prestressed concrete box girder, 24 stays tuned under permanent loads, SIA 261 load model 1 traffic, braking and temperature solved to second order and 15 limit state checks. The displayed traffic is solved for every frame; the permanent state, the stay tuning and the check envelopes are computed once at load.

The bridge is fictional. I sized it like a preliminary design: every quantity comes from a calculation or an assumption written on this page, with its source. The code values are taken from SIA 260:2013, SIA 261:2020 and SIA 262:2013: they carry the mention “taken from SIA” in the table of assumptions, with the clause or table. Criteria that SIA does not set have their own status: “design choice” (a criterion stricter than the code, often taken from the Eurocodes) or “project assumption” (a value from usual practice, with its source). What the model does not compute is listed in chapter 12. This page shows a method: it does not replace a construction design, reading the standards, or a check by an engineer.

The model code is public and readable as is: modele.js for the calculation, hypotheses.js for all the data.

01 · The structure

A box girder with a central stay plane, a single pylon

G, yG = 1.674 m16.00 m6.50 m2.50 mwebvoid
Box girder cross-section, outlines taken from hypotheses.js. The diaphragms (one every 10 m, at each anchorage) are smeared into a distributed load.
Preliminary design
QuantityValueBasis
Deck width16.00 m2 edges of 0.75 m, 2 carriageways of 5.3 m, 4.5 m central reserve: 3.0 m mast and, on each side, a 0.50 m rigid barrier with 0.25 m clearance
Box depth2.50 mL / h = 140 / 2.5 = 56. Central stay plane: the closed box carries torsion alone
A9.040 m²equivalent thickness 0.56 m
I7.419 m⁴efficiency ρ = I / (A vbot vtop) = 0.59
vbot, vtop1.674; 0.826 mdistance from the centroid to the bottom and top fibres
Wbot, Wtop4.431; 8.985 m³I / v
ConcreteC50/60, Ec = 38.7 GPaEcm = 10,000 fcm1/3, fcm = 58 MPa; deck and pylon
g1241.0 kN/m25 A = 226.0 kN/m, plus 15.0 kN/m of diaphragms (one at each anchorage)
g248.9 kN/masphalt 9 cm over 10 m, central reserve, curbs, safety barriers, parapets, ducts
Pylonb from 7.0 to 4.5 mbox 3.0 m wide, 0.70 m walls; base: A = 12.04 m², I = 62.3 m⁴; head: A = 8.54 m², I = 18.8 m⁴
Stays31 to 85 T15S strandsAp = 150 mm², fpk = 1,860 MPa, E = 195 GPa; for each stay, the smallest available anchorage size that keeps V5 (SLS, 0.45 fpk) and V6 (ULS, fpd) below 0.995, second order, braking and temperature included
Internal prestressP1 = 8,023 kN; P2 = 68,192 kNcentred 27 T15S tendons: 2 over 280 m, 17 in each 80 m end zone; σp0 = 0.71 fpk = 1,320.6 MPa at the jack, σp∞ = 990 MPa after 25 % losses
Supportssliding abutments, fixed pylonabutments: v fixed, u and θ free; pylon base: u, v, θ fixed; deck built into the pylon at node 28

A single stay plane on the centre line keeps both carriageways clear. The price: the box alone must carry the torsion from eccentric traffic, hence a closed section that is deep enough and wide enough at the soffit.

The pylon rises 64 m above the deck, 0.46 times the span, and carries the anchorages from 36 to 58 m every 2 m (semi-fan). On the deck the anchorages are every 10 m, from 20 to 130 m from the pylon. The 4.5 m central reserve lets the 3.0 m mast pass between two rigid barriers.

02 · The model

A plane frame with 217 degrees of freedom

node 0node 562857, fixed73, headk = 0k = 11140 m140 m64 m20 manchors from 36 to 58 m
74 nodes: 57 on the deck (every 5 m), 17 on the pylon. 56 deck beams, 17 pylon beams, 24 bars for the stays. Node 28 is shared by the deck and the pylon.

The deck and the pylon are Euler-Bernoulli beams (3 degrees of freedom per node: u, v, θ). Shear deformation is neglected: the span between anchorages (10 m) is 4 times the box depth, and shear adds about 1 % at most to the traffic deflection (estimated with the web area). The pylon properties are taken at the middle of each element.

ke=[a00−a000bc0−bc0cd0−ce−a00a000−b−c0b−c0ce0−cd],a=EAL,b=12EIL3,c=6EIL2,d=4EIL,e=2EIL
Stiffness matrix of a beam in local axes. The vertical pylon is rotated by 90°: kglobal = TT k T.
kh=Eeq,hAhLhggT,Nh=Eeq,hAhLhg·dh+th
Stay: pin-ended bar of chord Lh, vector g = [−c, −s, 0, c, s, 0] from the deck anchorage to the pylon anchorage, tuning pretension th.

K (222 × 222) is assembled, the 5 fixed degrees of freedom are removed, then Kff (217 × 217) is factorised once by Cholesky, for each stiffness in use (first order, second order SLS and ULS). A frame then only costs two forward and backward substitutions, about 0.3 ms. The abutments only fix v: the deck is held horizontally by the pylon alone. Their bearings are anchored (design choice): they hold v in both directions, in compression as in tension.

σsup=NA−MWsup,σinf=NA+MWinf
Top and bottom fibre stresses (N > 0 in tension, M > 0 puts the bottom fibre in tension).

03 · Permanent loads and tuning

The stays are tuned so that the deck remains at its design level

Permanent loads G0: g1 + g2 = 289.8 kN/m on the deck, the pylon self-weight (25 A per metre) and the weight of each stay (γh = 95 kN/m³ per m² of steel, sheaths and wax included, 21.4 to 172.4 kN), half at each anchorage. The deck weighs 81.2 MN.

Built at geometric length, the bridge would sag 577 mm near x = 52.5 m under its own weight, with deck moments from −178 to +131 MNm. On a real site the length of each stay is adjusted. The model does the same with the influence matrix method.

CxX=−dX[r],xX=[t0…t23,Δp],dX*=dX+∑hthdTh+ΔpdD
Tuning: 25 conditions, 25 unknowns. C collects the displacements v at rows r due to a unit pretension in each stay (24 columns) and a unit elongation of the pylon below the deck (column 25).
  • Conditions under G0 + P: v = 0 at the 24 deck anchorages and v = 0 at node 28 (junction with the pylon).
  • Δp offsets the shortening of the pylon below the deck (102.3 MN at the base). On site it is the fabrication camber. Δp = +4.42 mm.
  • Result: under permanent loads the deck is a continuous beam on rigid supports (abutments, 24 anchorages, pylon). The moments range from −11.0 MNm at the pylon to +5.5 MNm, and the pylon head does not move (u = 0 mm, with no condition imposed: it comes from symmetry).
  • The vertical components of the stays carry 73.6 MN, each abutment 1,143 kN.
Eeq=E1+(γlh)2E12σ3
Ernst equivalent modulus of a sagging stay: lh horizontal projection, γ = 95 kN/m³, σ permanent stress (at least 1 MPa). Iteration: Eeq = E, tuning, new stress, new modulus, until the relative change is below 10−9. Converges in 2 iterations (change 0.91 % then 8e−15).

The stays work at 0.32 to 0.41 fpk under permanent loads: Eeq / E remains between 0.9910 and 0.9999. The Ernst effect is small here because the stays are well tensioned. Traffic is superposed with this tangent modulus held fixed.

Stays of the left span (the right span is symmetric). x: anchorage position; t: tuning pretension; ΔNQ: traffic envelope, SLS second order.
kx (m)Lh (m)strandsEeq / Et (kN)Nperm (kN)σperm / fpkΔNQ+ (kN)ΔNQ− (kN)η V5η V6
012041.2480.99995,7145,4280.405493−120.9900.813
111048.4310.99942,9442,7650.320482−110.8390.693
210056.6430.99934,6444,4030.367815−350.9690.802
39065.3430.99894,6894,4550.371874−420.9890.820
48074.4480.99845,2214,9680.371964−310.9860.818
57083.8550.99735,6425,3310.3471,026−10.9230.764
66093.3550.99726,0345,7050.37293200.9650.797
750103.0610.99596,4416,0640.356885−20.9130.753
840112.7610.99576,7596,3720.374710−170.9320.767
930122.5610.99567,1546,7610.397565−790.9660.792
1020132.4610.99487,1396,7440.396573−2480.9660.793
1110142.4850.99108,8278,2780.349963−7550.8780.724

04 · Internal prestress

Centred compression where the stays give none

The stay axial force compresses the deck near the pylon, but hardly at all near the abutments. Without internal prestress, the bottom fibre would reach +9.8 MPa near x = 35 m under characteristic (rare) traffic: the uncracked linear analysis would no longer hold. So I modelled it.

Centred, straight 27 T15S tendons: 2 over the full length (P1 = 8,023 kN) and 17 in each 80 m end zone (P2 = 68,192 kN), anchored at the abutments and in the diaphragms at nodes 16 and 40. Jacking stress σp0 = 0.71 fpk = 1,320.6 MPa, below the SIA 262:2013 limit of 0.75 fpk (4.1.5.2.1, eq. (21)): a design choice, explained below with V14. Lump-sum total losses of 25 % (project assumption; SIA 262 gives a loss calculation method, 4.1.5.3, which I did not apply): σp∞ = 990 MPa, above 0.45 fpk = 837 MPa (4.1.5.2.3, V15). The tendons are centred because the tuned deck behaves like a beam on rigid supports every 10 m: an eccentric tendon would mostly create secondary moments there. The deck needs compression.

Just after tensioning, SIA 262 limits the steel stress to 0.70 fpk (4.1.5.2.2, eq. (22)). The maximum along the tendon lies at the end of the zone relaxed by the wedge draw-in, in the last tendon tensioned, which the elastic shortening from later tendons does not relieve. For a straight tendon with the friction of eq. (24): σp,max = σp0 − √(Ep Δs μ Δφ σp0), with μ = 0.18, Δφ = 0.005 rad/m and Δs = 6 mm (project assumptions, usual approval values). The draw-in affects 31.8 m of tendon, less than the length tensioned from one anchorage. With 0.75 fpk at the jack, σp,max would be 1,357 MPa = 0.729 fpk and V14 would exceed 1. Hence 0.71 fpk at the jack: σp,max = 1,283 MPa, ηV14 = 0.986. V13 takes every tendon at this maximum, which overestimates the concrete compression at tensioning.

The number of tendons comes from decompression under the frequent combination (V4). This criterion comes from EN 1992-2 (Table 7.101N); SIA 262 has none, so it is a design choice, applied with the SIA 260 ψ for traffic, braking and temperature. The temperature gradient of chapter 06 weighs heavily: up to 2.65 MPa of tension in the bottom fibre. I kept the smallest number of tendons that keeps V4 below 1 even with 2 more points of losses (η = 0.969 with 25 %, 0.990 with 27 %) and V8 below 1 with 2 points fewer (0.981); the P state is then scaled by the ratio of the final stresses. Units of 27 strands rather than 19 give the same force with fewer ducts and anchorages. Preliminary design: tendon stops idealised in one section, 80 m from each abutment; the staggering is to be studied in the detailed design.

Final permanent state: N = −76.2 MN at the abutments, −62.9 MN at the pylon and −116.3 MN where it peaks (x = 70 to 80 m, end of the end zone). σtop ranges from −12.99 to −5.49 MPa, σbot from −13.41 to −5.48 MPa. Only the long-term state is checked.

05 · Traffic and braking

SIA 261 load model 1 and braking, reduced to the plane

For the lane layout, each carriageway counts 5.25 m, including the trafficable clearance in front of the central reserve barrier: SIA 261 (Table 9) does not say where the width is measured, and I took the most unfavourable reading (project assumption). It carries one 3.0 m lane and 2.25 m of remaining area. The model is plane: the loads of all lanes are summed across the width and the two tandems sit at the same position. The torsion from eccentric lanes is carried by the box and stays outside the model.

qUDL=αq1qk1w+αqiqk2w+αqrqkr(b1+b2−2w),Q=αQ1Qk1+αQ2Qk2
qUDL = 0.9 × 9.0 × 3 + 0.9 × 2.5 × 3 + 0.9 × 2.5 × 4.5 = 41.2 kN/m; Q = 0.9 × 300 + 0.9 × 200 = 450 kN per axle, 2 axles 1.2 m apart.

All adjustment factors are 0.9 (SIA 261:2020, 10.3.2), for the axles as for the distributed load of every lane and of the remaining area. The dynamic factor of 1.3 on axles within 3 m of a joint (10.3.4) is a local effect (slab, joint, bearing): it is not applied to the global forces of the model.

Braking and acceleration (SIA 261:2020, 10.2.4, eq. (20)): QBk = 1.2 αQ1 Qk1 + 0.1 αq1 qk1 b1 l = 324 + 680.4 = 1,004.4 kN, capped at 900 kN (b1 = 3 m, l = 280 m between joints). It acts together with load model 1 (10.2.6.1), at carriageway level, 0.92 m above the box axis. The abutments slide: the whole force goes to the pylon. The model places QBk at either abutment, in either direction, and adds the largest effect of these cases on the unfavourable side of each output, with ψ0 = ψ1 = 0.75 and ψ2 = 0 (SIA 260:2013, Annex B, Table 6, horizontal forces). SLS effects: 14.5 MNm at the pylon base (±0.85 MPa), deck axial force up to 943 kN (0.10 MPa). Braking does not count in V10 (load model 1 alone, Table 7, note 4). Transverse braking and the torsion from braking in the axis of lane 1 stay outside the model.

  • On the home page: the tandem follows the pointer and the distributed load covers the whole deck, with an intensity kq from 0 to 1 as you scroll. A frame solves this traffic, then adds the permanent state.
  • Rest image (tandem at 42 m): deflection 45.9 mm at x = 47.5 m, pylon head moved by −17.9 mm, stay ΔN from −134 to +192 kN.
  • Full distributed load alone: deflection 86.1 mm at x = 52.5 m. Tandem at 70 m with the distributed load: deflection 127.2 mm, total σbot from −16.05 to −3.74 MPa.
E+=qUDL∑emax(0,re)+max(0,maxxTr(xT))
Envelopes for the checks: distributed load placed element by element where it is unfavourable (56 cases), tandem moved every 0.5 m (561 positions), once for the SLS and once for the ULS. Computed once, outside the animation loop (about 250 ms).

06 · Temperature

Uniform for the pylon and the stays, linear in the deck

SIA 261:2020 splits the temperature change into a uniform part T1, a linear part T2 and a non-linear part T3, not considered as a rule (7.2.1). Uniform part (Table 6): ±20 °C for prestressed concrete, ±30 °C for steel, αT = 10 × 10−6/°C (Table 5). The deck slides at the abutments. If the whole bridge expanded with the same coefficient about the junction between the deck and the pylon, nothing would be restrained; only the elongation of the 20 m of pylon below the deck is left, 4.0 mm, which lifts the deck at the pylon. The steel stays take 30 °C instead of 20: the 10 K difference, in the same direction, enters as a pretension −Eeq A αT ΔT. This is a project assumption: SIA 261 considers differences between zones only in particular cases (7.2.3), and a cable-stayed bridge is one; EN 1991-1-5 (6.1.6) recommends 10 K for light-coloured stays. Effect: up to 185 kN in stay k = 11.

Linear part in the deck (Table 7, interpolated for h = 2.5 m): top face warmer by 9 °C or cooler by 3.25 °C. Each element receives the free curvature αT T2 / h. The deck, continuous and held every 10 m by the stays, is almost fully restrained: for +9 °C, the full restraint moment EI κ is 10.3 MNm and the bottom fibre gets up to +2.65 MPa of tension (x = 90 m). This is what weighed most on the prestress. The gradient in the mast (sun on one face) stays outside the model.

T1 and T2 are superposed, each in its unfavourable direction. Temperature is one more variable action, with ψ0 = 0.6, ψ1 = 0.6 and ψ2 = 0.5 (SIA 260:2013, Annex B, Table 6); it enters every serviceability check, leading or not (chapter 07). At the ULS it stays in V6 (stays) and in the design reactions of the abutments (anchorage and bearings). For the concrete (V8, V9 and ηt), its forces are neglected: SIA 262:2013 (4.1.2.2) allows this for restrained deformations when the deformation capacity is sufficient and instability is excluded (ULS αcr = 5.64). This is a project assumption.

07 · Combinations

Two variable actions, each leading in turn

EG: tuned G0 state (pretensions included); EP: tuned prestress. Q: traffic, i.e. ETS + EUDL + |EB| (tandem, distributed load and braking, to second order); T: temperature, |T1| + T2 on the unfavourable side. Subscript d: ULS stiffness and axial forces.
Combination (SIA 260:2013)ExpressionValues
SLS characteristic (rare), eq. (20)EG + EP + max(Q + ψ0,T T ; ψ0 Q + T)ψ0 = 0.75 (traffic and braking), ψ0,T = 0.6
SLS frequent, eq. (21)EG + EP + max(ψ1 Q + ψ2,T T ; ψ1,T T + ψ2 Q)ψ1 = 0.75, ψ2 = 0, ψ1,T = 0.6, ψ2,T = 0.5
SLS quasi-permanent, eq. (22)EG + EP + ψ2 Q + ψ2,T Tψ2 = 0, ψ2,T = 0.5
ULS type 2, eq. (16)γG EG + γP EP + γQ max(Qd + ψ0,T Td ; ψ0 Qd + Td)γG = 1.35 or 0.80, γP = 1.0, γQ = 1.50 (Table 1; γP: project assumption). Concrete (V8, V9): Td = 0

The SIA 260 rare load case corresponds to the EN 1990 characteristic combination. The model has two variable actions: traffic (load model 1 and braking act together, SIA 261 10.2.6.1) and temperature. At each point each one is tried as the leading action, the other taking its ψ factor, and the more unfavourable one is kept.

The stay pretension is treated as a permanent action tied to the weight it balances: it takes γG with G. In the envelopes each variable part is taken on its unfavourable side and set to zero when it helps. At the ULS both values of γG are tried and the worse one is kept, for the checks as for the state on screen.

08 · Second order

A pylon under 112 MN of compression calls for second order

At SLS characteristic (rare) the pylon base carries 112.5 MN and the deck up to 119.2 MN of compression. When traffic displaces the structure, these forces create additional moments. Traffic is therefore solved with the tangent stiffness K + KG(N), N being the axial forces of the combination with all the traffic (distributed load everywhere, tandem at the pylon), held fixed: factors 1 for the SLS, γG,sup, γP and γQ for the ULS (pylon base at 153.3 MN). Holding N fixed keeps superposition, and a frame remains one forward-backward substitution per stiffness.

The tuned states EG and EP stay at the reference geometry (deck at its level, head still): their second-order effect is negligible and they are computed to first order.

kG=N30L[363L−363L3L4L2−3L−L2−36−3L36−3L3L−L2−3L4L2],kG,h=NhLh[nnT]
Consistent geometric stiffness of a beam (dof vi, θi, vj, θj) and of a stay (translations, n normal to the chord). Compression makes it negative, tension in the stays makes it positive.
(K+KG(N))d=FQ,M(x)=M1(x)+N(v(x)−vi),det(K+αcrKG)=0
The moment in each deck element adds N (v(x) − vi) to the first-order moment. αcr: critical factor for in-plane buckling under the same N, the smallest positive eigenvalue, computed by power iteration and checked with a Sturm sequence.
  • αcr = 5.96 at the SLS and 5.64 at the ULS. Below 10, second order cannot be ignored; above 3, the linearised analysis is enough (project assumption: a model check criterion, EN 1993-1-1 practice, not an SIA requirement).
  • Distributed load on the left span and tandem at 53.75 m: second order increases the deflection by 15.7 %, the head displacement by 17.7 %, the base moment by 15.2 % and the force in the most loaded stay (k = 5) by 12.0 %.
  • The global estimate 1 / (1 − 1 / αcr) = 1.202 bounds these values. It does not cover every output: with the tandem alone at x = 2 m, the force in stay k = 11 increases by 35.2 %. So the model solves K + KG for every traffic case.

09 · Checks

15 utilisation ratios below 1, second order included

Checks on the second-order traffic envelopes, at the 280 deck control points (2 fibres), the 24 stays, the 2 pylon sections and, for deflections, the 225 deck stations (l = 140 m span). η ≤ 1: satisfied.
N°ItemCombinationFormulaDemand / limitηLocationCriterion status
V1Deck concrete, compressionSLS char. (rare)η = −min σrare / (0.60 fck)−20.57 MPa / −30.00 MPa0.686x = 140 m, bottom fibredesign choice
V2Deck concrete, compression (linear creep)SLS q.-perm.η = −min σqp / (0.45 fck)−14.10 MPa / −22.50 MPa0.626x = 70 m, bottom fibredesign choice
V3Deck concrete, tension (uncracked section)SLS char. (rare)η = max σrare / σt,lim2.87 MPa / 4.10 MPa0.700x = 36.25 m, bottom fibredesign choice
V4Deck decompressionSLS freq.η = Δσfreq / (σlim − σperm)σfreq = −0.33 MPa, limit 00.969x = 35 m, bottom fibredesign choice
V5Stay stressSLS char. (rare)η = (Nperm + ΔNrare) / (Ah 0.45 fpk)829 MPa / 837 MPa0.990stay k = 0, left spanproject assumption
V6Stay resistanceULSη = (γG NG + γP NP + γQ ΔNrare,d) / (Ah fpd)1,140 MPa / 1,391 MPa0.820stay k = 3, left spanproject assumption
V7Stay remains in tensionSLS char. (rare)η = −ΔNrare,min / Npermmin N 7,376 kN0.109stay k = 11, left spandesign choice
V8Deck concrete, compression, elastic criterionULSη = −min σEd / fcd(ηt), no temperature−27.55 MPa / −28.11 MPa0.980x = 140 m, bottom fibredesign choice
V9Pylon concrete, compression, elastic criterionULSη = −min σp,Ed / fcd(ηt), no temperature−22.97 MPa / −28.11 MPa0.817pylon, base, x− facedesign choice
V10Deflection, comfortSLS freq.η = max |ψ1 wLM1| / (l / 500)157.6 mm / 280 mm0.563x = 53.75 mtaken from SIA
V11Deflection, appearanceSLS q.-perm.η = max |wperm + ψ2 wQ + ψ2,T wT| / (l / 700)11.7 mm / 200 mm0.059x = 40 mtaken from SIA
V12Carriageway joint at the abutmentsSLS freq.η = max |vbearing ∓ e θbearing| / vlim2.70 mm / 5 mm0.540abutment, x = 0 mtaken from SIA
V13Concrete at tensioningtensioningη = −min σc / (0.6 fck(t)), outside anchorage zones−15.90 MPa / −30.00 MPa0.530x = 70 m, bottom fibretaken from SIA
V14Prestressing steel after lockingtensioningη = σp,max / (0.70 fpk), just after locking1,283 MPa / 1,302 MPa0.986all tendonstaken from SIA
V15Prestressing steel, final stresslong termη = 0.45 fpk / σp∞990 MPa / 837 MPa0.845all tendonstaken from SIA
  • Highest η: V5 = 0.990, V14 = 0.986, V8 = 0.980, V4 = 0.969. V5: 0.990 on stay k = 0. Each stay has the smallest available anchorage size that keeps V5 and V6 below 0.995: 31 to 85 strands. The 0.45 fpk limit is a project assumption (fib Bulletin 30, Sétra): SIA gives none for stays.
  • V8 (η = 0.980, x = 140 m, bottom fibre) and V9 (η = 0.817) are simplified elastic criteria, hence design choices: the ULS fibre stress, with the prestress counted as an action (γP = 1.0), is compared to fcd. Only fcd, ηfc and ηt come from SIA 262; the section resistance (axial force and bending with the reinforcement, 4.3) is not computed. ηt (4.2.1.3) is computed point by point: the permanent share of the ULS effect is 45 % at the governing point of V8 and 51 % at the pylon base, hence ηt = 1.0; it is 0.85 only at 8 points out of 560, near the abutments, where η is low.
  • V1 to V4 are design choices taken from EN 1992, stricter than SIA 262, which does not limit these service stresses. V3 (η = 0.700) is also a validity check: the model assumes an uncracked section, with σt,lim = 4.10 MPa (tractionCar × fctm). Cracking: increased requirements (SIA 262:2013, 4.4.2.2), as a project assumption; this check is made on the reinforcement (Table 17, Figure 31) and outside the model.
  • V13 to V15: SIA 262 requirements on the prestress. V13 (4.1.5.2.4, eq. (23)): at tensioning, outside the 2.5 m anchorage zones, σc = −15.90 MPa at most (x = 70 m, bottom fibre), against 0.6 fck(t) = 30 MPa, tensioning at 28 days (project assumption). V14 (4.1.5.2.2): 1,283 MPa just after locking, against 1,302 MPa (chapter 04). V15 (4.1.5.2.3): σp∞ = 990 MPa, at least 837 MPa. Non-linear creep (3.1.2.6.3, eq. (14)): under the quasi-permanent combination, σc = −14.10 MPa = 0.282 fck, below the 0.45 fck threshold: βσc = 1.00.
  • V10 to V12: deflections and carriageway joint, SIA 260:2013, Annex B, Table 7 (indicative values). V10: the deflection under the frequent value of load model 1 alone is 157.6 mm at x = 53.75 m, against l / 500 = 280 mm. V11: ψ2 = 0 for traffic but 0.5 for temperature; the tuning sets v = 0 at the anchorages under G + P, at most 11.7 mm remain, mostly the gradient curvature, counted without deducting any precamber. Long-term effects (creep, shrinkage, relaxation) are not computed: the real appearance check is still to be done. V12: SIA 260 puts the carriageway joint limit in the frequent (21) column of Table 7. The abutments are sliding bearings at v = 0, but the deck end rotates, and the joint sits e = 0.50 m from the bearing axis (design choice). The displacement at the joint v = ∓ e θ is 2.70 mm under G + P and the frequent part (traffic, braking, temperature), against 5 mm. Bearing settlement remains outside the model.
  • Robustness: with 2 more points of losses, V4 = 0.990 and V15 = 0.868; with 2 points fewer, V8 = 0.981. Every η stays below 1.
  • On the home page the same η are recomputed for the state on screen: the traffic in the frame instead of the envelopes, its braking per eq. (20) and temperature as an accompanying action, with the factors of each combination. The η mode colours the deck by V1 and V3 at each station and the stays by V5. The live values line also gives the frequent deflection of the frame and its ratio V10.

Findings without η. Max traffic deflection (rare case) 210.1 mm at x = 53.75 m, i.e. L/666; 162.6 mm with the distributed load on one span only; pylon head up to 90.8 mm. Abutment: 1,143 kN under permanent loads, 219 kN at least at SLS characteristic (rare). The abutment bearings are anchored (design choice): at the ULS the design reaction ranges from −472 kN (tension) to 5,625 kN (compression). Design force of the anchorage: Fd,anchorage = 472 kN, at the abutment x = 0 m (same value at the other abutment, by symmetry), with γG,inf = 0.80 on the favourable permanent load and traffic leading (load model 1 and braking), temperature accompanying with ψ0,T = 0.6, on the unfavourable side. Maximum bearing compression at the ULS: 5,625 kN at the abutment x = 0 m, with γG,sup = 1.35 and traffic leading (load model 1 and braking), temperature accompanying with ψ0,T = 0.6.

10 · Assumptions

Every value, its source and its status

This table is generated from hypotheses.js, the only file that holds values. No code text is copied, only values and their references.

  • taken from SIA: a value taken from SIA 260:2013, SIA 261:2020 or SIA 262:2013 (editions licensed to HES-SO), with the exact clause or table (“SIA 26x:20xx, …” under the mention).
  • design choice: a criterion or dimension chosen for the project, not an SIA requirement; the source says where it comes from (often a Eurocode).
  • project assumption: a value SIA does not set, taken from usual practice, with its source (fib, Sétra, approvals, EN 1991-1-5).
  • product assumption: a supplier value, to be confirmed with the chosen product.
Code values and check criteria69 rows
Model assumptions: Code values and check criteria
QuantityValueUnitSourceStatus
Unit weight of reinforced concrete25kN/m³SIA 261:2020, Annex A, Table 28taken from SIASIA 261:2020, Annex A, Table 28
Unit weight of asphalt surfacing24kN/m³SIA 261:2020, Annex A, Table 28taken from SIASIA 261:2020, Annex A, Table 28
Characteristic compressive strength, C50/6050MPaSIA 262:2013, Table 3taken from SIASIA 262:2013, Table 3
Offset fcm − fck8MPaSIA 262:2013, 3.1.2.2.2, eq. (6). fcm = 58 MPa for C50/60, as in Table 3taken from SIASIA 262:2013, 3.1.2.2.2, eq. (6)
Coefficient kE of Ecm = kE ∛fcm (MPa)10,000SIA 262:2013, 3.1.2.3.3, eq. (10). Low end of the 10,000 to 12,000 range for alluvial gravel: a cautious choice for deflectionstaken from SIASIA 262:2013, 3.1.2.3.3, eq. (10)
Mean tensile strength fctm, C50/604.1MPaSIA 262:2013, Table 3. Tabulated value (the former formula 0.30 fck^(2/3) came from EN 1992-1-1)taken from SIASIA 262:2013, Table 3
Partial factor for concrete γc1.5SIA 262:2013, 2.3.2.6. fcd = ηfc ηt fck / γc, eq. (2)taken from SIASIA 262:2013, 2.3.2.6
Load duration factor ηt, general case1SIA 262:2013, 4.2.1.3. ηt = 1.0 if the share of permanent loads in the design effect does not exceed 90 %taken from SIASIA 262:2013, 4.2.1.3
Load duration factor ηt, permanent loads predominant0.85SIA 262:2013, 4.2.1.3. Applied point by point (deck and pylon) where the permanent share of the ULS effect exceeds the threshold belowtaken from SIASIA 262:2013, 4.2.1.3
Threshold of the permanent load share in the design effect for ηt = 0.850.9SIA 262:2013, 4.2.1.3. Permanent share = (γG G + γP P) / (γG G + γP P + γQ Q) at each checked point, ULS effects of V8 and V9taken from SIASIA 262:2013, 4.2.1.3
Reference of ηfc = ∛(30 / fck) ≤ 130MPaSIA 262:2013, 4.2.1.2, eq. (26)taken from SIASIA 262:2013, 4.2.1.2, eq. (26)
Maximum concrete compression during tensioning and just after, outside anchorage zones0.6× fck(t)SIA 262:2013, 4.1.5.2.4, eq. (23). Check V13taken from SIASIA 262:2013, 4.1.5.2.4, eq. (23)
Minimum fck(t) at the time of tensioning0.3× fckSIA 262:2013, 4.1.5.2.4taken from SIASIA 262:2013, 4.1.5.2.4
Non-linear creep threshold: above it, φ is multiplied by βσc = e^(1.5 (σc / fck − 0.45))0.45× fckSIA 262:2013, 3.1.2.6.3, eq. (14). Indicator shown with V2 (quasi-permanent combination)taken from SIASIA 262:2013, 3.1.2.6.3, eq. (14)
SLS characteristic (rare) compression limit: k1 fck (V1)0.6× fckDesign choice, not an SIA requirement: SIA 262 limits concrete compression only at tensioning (4.1.5.2.4). EN 1992-1-1 7.2(2) criterion, k1 = 0.6 (classes XD, XF, XS: longitudinal cracks)design choice
SLS quasi-permanent compression limit: k2 fck (V2, linear creep)0.45× fckDesign choice, not an SIA requirement: keep creep linear. EN 1992-1-1 7.2(3), k2 = 0.45. In SIA 262, 0.45 fck is the βσc threshold (3.1.2.6.3), not a limitdesign choice
SLS characteristic (rare) tensile limit (V3, uncracked section, model assumption)1× fctmDesign choice, not an SIA requirement: keeps the uncracked linear analysis valid. Transition to the cracked state at fctm per SIA 262 4.2.1.14; EN 1992-1-1 7.1(2). Must stay > 0 (otherwise V4 is the check)design choice
Decompression under SLS frequent: σ ≤ 0 at both fibres (V4)0MPaDesign choice, not an SIA requirement: SIA 262 has no decompression criterion. EN 1992-2 7.3.1, Table 7.101N (bonded tendons, classes XD, XS)design choice
Cracking requirementsaccruesSIA 262:2013, 4.4.2.2.5 (increased requirements, set in the basis of design per 4.4.2.2.2). Checked on the reinforcement (Table 17, Figure 31; frequent combination Δσs ≤ fsd − 80 MPa), outside the modelproject assumption
Area of one Y1860S7-15.7 strand150mm²SIA 262:2013, Table 7taken from SIASIA 262:2013, Table 7
Strand tensile strength1,860MPaSIA 262:2013, 3.3.2.2, Table 7taken from SIASIA 262:2013, 3.3.2.2, Table 7
0.1 % proof stress fp0.1k1,600MPaSIA 262:2013, Table 7. The former value 1,640 MPa came from EN 10138-3taken from SIASIA 262:2013, Table 7
Strand elastic modulus195GPaSIA 262:2013, 3.3.2.4.2taken from SIASIA 262:2013, 3.3.2.4.2
Partial factor for prestressing steel γs (fpd = fp0.1k / γs)1.15SIA 262:2013, 2.3.2.6; eq. (5) in 2.3.2.5. fpd = 1,390 MPa in Table 10. Also applied to the stays as an assumption: SIA 262 does not cover stays; rules specific to stays (EN 1993-1-11 section 6, fib Bulletin 30) give a lower design resistance, about 0.70 to 0.75 fpktaken from SIASIA 262:2013, 2.3.2.6; eq. (5) in 2.3.2.5
Stay stress limit at SLS characteristic (rare) (V5)0.45× fpkProject assumption, usual practice: SIA sets no limit for stays. fib Bulletin 30, CIP / Sétra 2001 recommendations, EN 1993-1-11 section 7project assumption
Maximum jacking stress of the internal prestress, during tensioning0.75× fpkSIA 262:2013, 4.1.5.2.1, eq. (21). Limit of the jacking stress (stress adopted: kSigmaVerin); the former second term 0.9 fp0.1k came from EN 1992-1-1taken from SIASIA 262:2013, 4.1.5.2.1, eq. (21)
Maximum prestressing steel stress just after tensioning (V14)0.7× fpkSIA 262:2013, 4.1.5.2.2, eq. (22)taken from SIASIA 262:2013, 4.1.5.2.2, eq. (22)
Minimum prestressing steel stress after all losses (V15)0.45× fpkSIA 262:2013, 4.1.5.2.3taken from SIASIA 262:2013, 4.1.5.2.3
Tandem axle load, lane 1300kNSIA 261:2020, 10.2.2.2, Table 10taken from SIASIA 261:2020, 10.2.2.2, Table 10
Tandem axle load, lane 2200kNSIA 261:2020, 10.2.2.2, Table 10. Tandems of lanes 1 and 2 in the same section (10.2.2.3)taken from SIASIA 261:2020, 10.2.2.2, Table 10
Uniformly distributed load, lane 19kN/m²SIA 261:2020, 10.2.2.5, Table 10taken from SIASIA 261:2020, 10.2.2.5, Table 10
Uniformly distributed load, lane 22.5kN/m²SIA 261:2020, 10.2.2.5, Table 10taken from SIASIA 261:2020, 10.2.2.5, Table 10
Uniformly distributed load, remaining area2.5kN/m²SIA 261:2020, 10.2.2.6, Table 10taken from SIASIA 261:2020, 10.2.2.6, Table 10
Coefficient αQ10.9SIA 261:2020, 10.3.2. Normal case; the 10.3.3 reduction does not apply (2 carriageways)taken from SIASIA 261:2020, 10.3.2
Coefficient αQ20.9SIA 261:2020, 10.3.2taken from SIASIA 261:2020, 10.3.2
Coefficient αq10.9SIA 261:2020, 10.3.2. The former value 0.5 does not exist in SIA 261:2020taken from SIASIA 261:2020, 10.3.2
Coefficient αqi (i ≥ 2)0.9SIA 261:2020, 10.3.2. The former value 1.0 was the EN 1991-2 onetaken from SIASIA 261:2020, 10.3.2
Coefficient αqr (remaining area)0.9SIA 261:2020, 10.3.2. The former value 1.0 was the EN 1991-2 onetaken from SIASIA 261:2020, 10.3.2
Notional lane width3mSIA 261:2020, 10.2.1.1, Table 9. Carriageway narrower than 5.4 m: 1 lane of 3 m and a remaining areataken from SIASIA 261:2020, 10.2.1.1, Table 9
Spacing of the 2 tandem axles1.2mSIA 261:2020, 10.2.2.2, Figure 11taken from SIASIA 261:2020, 10.2.2.2, Figure 11
Braking: axle load coefficient, QBk = 1.2 αQ1 Qk1 + 0.1 αq1 qk1 b1 l1.2SIA 261:2020, 10.2.4.2, eq. (20)taken from SIASIA 261:2020, 10.2.4.2, eq. (20)
Braking: distributed load coefficient (b1 = lane 1 width, l = 280 m between joints)0.1SIA 261:2020, 10.2.4.2, eq. (20)taken from SIASIA 261:2020, 10.2.4.2, eq. (20)
Braking: maximum value of QBk900kNSIA 261:2020, 10.2.4.2. Acts with load model 1 (10.2.6.1), at carriageway level (10.2.4.1)taken from SIASIA 261:2020, 10.2.4.2
Dynamic factor on axle loads up to 3 m from an expansion joint (not applied: local effect, outside the model)1.3SIA 261:2020, 10.3.4. Concerns abutment reactions, the joint and the slab near the abutments, not the global forcestaken from SIASIA 261:2020, 10.3.4
Load factor, permanent actions, unfavourable γG,sup1.35SIA 260:2013, Table 1, limit state type 2taken from SIASIA 260:2013, Table 1, limit state type 2
Load factor, permanent actions, favourable γG,inf0.8SIA 260:2013, Table 1, limit state type 2. Note 1 of the table: choice of γG,sup or γG,inftaken from SIASIA 260:2013, Table 1, limit state type 2
Load factor for prestressing γP (on Pk, mean value after losses)1Project assumption, usual Swiss practice: Pk = mean value (SIA 260:2013, 3.2.2.5), γP per SIA 260:2013, 4.4.3.4, which refers to SIA 262. SIA 262 gives γP only for prestress introduction and anchorage zones (4.1.5.5.2)project assumption
Load factor for road traffic γQ (load model 1 and braking)1.5SIA 260:2013, Table 1, limit state type 2taken from SIASIA 260:2013, Table 1, limit state type 2
ψ0 of load model 1 (combination value), when temperature is the leading action0.75SIA 260:2013, Annex B, Table 6. Road bridges, load model 1taken from SIASIA 260:2013, Annex B, Table 6
ψ1 of the tandem system (frequent)0.75SIA 260:2013, Annex B, Table 6. Road bridges, load model 1 (same value for the whole model)taken from SIASIA 260:2013, Annex B, Table 6
ψ1 of the distributed load (frequent)0.75SIA 260:2013, Annex B, Table 6. Road bridges, load model 1 (same value for the whole model)taken from SIASIA 260:2013, Annex B, Table 6
ψ2 of the tandem system (quasi-permanent)0SIA 260:2013, Annex B, Table 6taken from SIASIA 260:2013, Annex B, Table 6
ψ2 of the distributed load (quasi-permanent)0SIA 260:2013, Annex B, Table 6taken from SIASIA 260:2013, Annex B, Table 6
ψ1 of the traffic horizontal forces (braking, frequent)0.75SIA 260:2013, Annex B, Table 6. Road bridges, horizontal forcestaken from SIASIA 260:2013, Annex B, Table 6
ψ0 of the traffic horizontal forces (braking), when temperature is the leading action0.75SIA 260:2013, Annex B, Table 6. Road bridges, horizontal forcestaken from SIASIA 260:2013, Annex B, Table 6
ψ2 of the traffic horizontal forces (quasi-permanent)0SIA 260:2013, Annex B, Table 6taken from SIASIA 260:2013, Annex B, Table 6
ψ0 of temperature effects (rare, ULS)0.6SIA 260:2013, Annex B, Table 6. Road bridges, temperature effectstaken from SIASIA 260:2013, Annex B, Table 6
ψ1 of temperature effects (frequent, temperature leading)0.6SIA 260:2013, Annex B, Table 6taken from SIASIA 260:2013, Annex B, Table 6
ψ2 of temperature effects (quasi-permanent, and frequent with traffic leading)0.5SIA 260:2013, Annex B, Table 6taken from SIASIA 260:2013, Annex B, Table 6
Coefficient of thermal expansion of concrete and steel1010⁻⁶/°CSIA 261:2020, 7.1.5, Table 5taken from SIASIA 261:2020, 7.1.5, Table 5
Uniform temperature change, prestressed concrete (deck and pylon)20± °CSIA 261:2020, 7.2.4, Table 6. Deck sliding at the abutments: only the elongation of the pylon below the deck (20 m) creates forcestaken from SIASIA 261:2020, 7.2.4, Table 6
Uniform temperature change, steel (stays)30± °CSIA 261:2020, 7.2.4, Table 6taken from SIASIA 261:2020, 7.2.4, Table 6
Section depths of the two table rows (linear interpolation between them)1; 3mSIA 261:2020, 7.2.5, Table 7, note 1taken from SIASIA 261:2020, 7.2.5, Table 7, note 1
Linear part T2k, top face warmer, concrete bridge, at the two depths12; 8°CSIA 261:2020, 7.2.5, Table 7. Interpolated for h = 2.5 mtaken from SIASIA 261:2020, 7.2.5, Table 7
Linear part T2k, top face cooler, concrete bridge, at the two depths−4; −3°CSIA 261:2020, 7.2.5, Table 7. Interpolated for h = 2.5 mtaken from SIASIA 261:2020, 7.2.5, Table 7
Comfort: minimum ratio l / w, w = deflection under the frequent value of load model 1 (frequent load case)500SIA 260:2013, Annex B, Table 7. Comfort row, note 4 (indicative value)taken from SIASIA 260:2013, Annex B, Table 7
Appearance: minimum ratio l / w, w = deflection under the quasi-permanent load case, precamber deducted700SIA 260:2013, Annex B, Table 7. Appearance row, notes 1 and 2 (indicative value)taken from SIASIA 260:2013, Annex B, Table 7
Carriageway joint at the abutments: maximum relative vertical displacement between the deck end and the abutment, frequent load case5mmSIA 260:2013, Annex B, Table 7. Carriageway transition joint row, frequent (21) column, notes 1 to 3 (indicative value)taken from SIASIA 260:2013, Annex B, Table 7
Minimum critical factor (model check) for amplifying first order by 1 / (1 − 1 / αcr)3Project assumption, model check criterion, not SIA: EN 1993-1-1 5.2.2(5)B practice. SIA 262 checks second order on the deformed system (4.3.7)project assumption
Design, project and product assumptions31 rows
Model assumptions: Design, project and product assumptions
QuantityValueUnitSourceStatus
Length of each span140mPortfolio geometry keptdesign choice
Deck element length5mMesh: 56 elements, anchors every 2 elementsdesign choice
Pylon node levels (deck axis = 0)−20; −10; 12; 24; 36; 38; 40; 42; 44; 46; 48; 50; 52; 54; 56; 58; 64mFixed base at −20 m, head at +64 m, anchors from 36 to 58 m every 2 m (semi-fan)design choice
Anchor distance from the pylon, stay k = 0 to 1120; 30; 40; 50; 60; 70; 80; 90; 100; 110; 120; 130m10 m spacing along the deckdesign choice
Overall width16m2 edges of 0.75 m + 2 carriageways of 5.0 m + 4.5 m central reserve (3.0 m mast, on each side a 0.50 m rigid barrier and 0.25 m clearance)design choice
Box girder depth2.5mSlenderness 140 / 2.5 = 56, central stay plane: torsionally stiff boxdesign choice
Outer outline (z, y from the soffit)(−3.25; 0); (3.25; 0); (4.25; 2); (8; 2.25); (8; 2.5); (−8; 2.5); (−8; 2.25); (−4.25; 2)m3.75 m cantilevers: slab 0.25 m at the tip, 0.50 m at the root; soffit 6.5 mdesign choice
Inner void outline(2.575; 0.25); (2.95; 0.4); (3.76; 2.02); (2.86; 2.22); (−2.86; 2.22); (−3.76; 2.02); (−2.95; 0.4); (−2.575; 0.25)mTop slab 0.28 m, bottom slab 0.25 m, webs 0.50 m (horizontal), haunchesdesign choice
Diaphragm at each anchorthickness 0.4 m; manhole 1 × 1.8 m; anchor block 1.5 m³; spacing 10 mSmeared into g1 as a distributed loaddesign choice
Deck concreteC50/60Prestressed deck, high compression near the pylondesign choice
Composition of g2surfacing 0.09 m over 10 m; central reserve 4.5 × 0.12 m of concrete; 2 curbs of 0.75 × 0.25 m; 4 safety barriers of 0.6 kN/m; 2 parapets of 0.5 kN/m; ducts 1 kN/mWaterproofing and asphalt on the carriageways; concrete fill in the central reserve (25 kN/m³, on the safe side if unreinforced); 2 edge barriers and 2 central reserve barriers. Weights of barriers, parapets and ducts: product assumptions (SIA 261 Annex A gives none)design choice
Pylon: tapered rectangular boxlongitudinal size b from 7 m (base) to 4.5 m (head); transverse width 3 m; walls 0.7 m; base at y = −20 m, head at y = 64 mSingle mast in the central reserve, C50/60 concrete, properties taken at mid-height of each elementdesign choice
Number of T15S strands, stay k = 0 (near the pylon) to 11 (near the abutment), symmetric48; 31; 43; 43; 48; 55; 55; 61; 61; 61; 61; 85strandsSized: max(NSLS,rare / (0.45 fpk Ap); NULS / (fpd Ap)), traffic to second order, braking and temperature included, rounded to the smallest available anchorage size that keeps η ≤ 0.995 (rounding margin). Stay k = 11: 85 strands (73 would give V5 = 1.004 with temperature); k = 7: 61 strands (55 would give 0.9996); k = 8: 61 strands since the SIA 261 α correctiondesign choice
Available stay anchorage sizes7; 12; 19; 22; 31; 37; 43; 48; 55; 61; 73; 85; 91; 109; 127strandsCommon series of parallel-strand stay systems, to be confirmed with the chosen supplierproduct assumption
Equivalent unit weight of the stay (per m² of steel)95kN/m³Steel 78.5 kN/m³ (SIA 261:2020, Annex A, Table 28) + individual sheath, wax and HDPE pipe (about +20 %), to be confirmed with the supplierproduct assumption
27 T15S prestressing tendons: continuity over 280 m and end zonescontinuity: 2 tendons of 27 strands, from x = 0 to 280 m; end zones: 17 tendons of 27 strands, from 0 to 80 m and from 200 to 280 mCompresses the zones where the stay axial force is low (near the abutments). Sized by decompression under the frequent combination (V4, design choice taken from EN 1992-2, with the SIA 260 ψ for traffic, braking and temperature): the smallest number of tendons that keeps V4 below 1 even with 2 more points of losses, and V8 below 1 with 2 points fewer. 27-strand units rather than 19: same steel (about 88,600 m of strand), 19 tendons instead of 27 near the abutments, hence fewer ducts and anchorages. End zones extended from 70 to 80 m. Preliminary design: tendon stops idealised in one section, the staggering is to be studied in the detailed designdesign choice
Lump-sum total losses at infinite time, from the jacking stress (friction, wedge draw-in, elastic shortening, creep, shrinkage, relaxation)0.25Project assumption, preliminary lump-sum value: SIA 262 gives a loss calculation method (4.1.5.3), not applied here. Robustness checked with 2 more points of lossesproject assumption
Chosen jacking stress of the internal prestress0.71× fpkDesign choice, below the SIA 262 limit of 0.75 fpk (eq. 21): with the friction and wedge draw-in below, the maximum stress just after locking of the last tensioned tendon stays below 0.70 fpk (eq. 22, V14). At 0.75 fpk it would reach about 0.73 fpkdesign choice
Friction coefficient μ between tendon and duct0.18Project assumption: usual value of the approvals of strand systems in steel ducts. SIA 262 refers to the system approval (4.1.5.3.3, eq. (24); 3.4.1.2)project assumption
Unintentional angular deviation Δφ per metre of tendon0.005rad/mProject assumption: usual approval value (SIA 262 4.1.5.3.3, eq. (24)). Straight tendons: only this term creates frictionproject assumption
Wedge draw-in at the live anchorage6mmProject assumption: usual approval value (SIA 262 4.1.5.3.1). Continuity tendons tensioned from both abutments, end tendons from the abutment. Maximum stress after locking, straight tendon with the friction of eq. (24): σp0 − √(Ep Δs μ Δφ σp0), reached at the end of the zone affected by the draw-inproject assumption
Concrete strength at tensioning: fck(t) / fck1× fckProject assumption: tensioning at 28 days, hence fck(t) = fck (SIA 262 Figure 1); must stay ≥ 0.3 (4.1.5.2.4)project assumption
Length of the internal prestress anchorage zones excluded from V13, on each side of each anchorage2.5mProject assumption: spreading length of the order of the box depth (Saint-Venant). In these zones, the limits of the system approval apply (SIA 262 4.1.5.2.5), outside the modelproject assumption
Temperature difference between the stays and the concrete, in the direction of T1k10KProject assumption: SIA 261 considers differences between zones of a structure only in particular cases (7.2.3); a cable-stayed bridge is one. Difference of the T1k of steel (±30 °C) and concrete (±20 °C) in Table 6, taken together; EN 1991-1-5 6.1.6 recommends 10 K for light-coloured stays. T1 and T2 are superposed, each in its unfavourable directionproject assumption
Temperature in the ULS concrete checks (V8, V9, ηt)négligéeProject assumption per SIA 262:2013, 4.1.2.2: at ULS, forces from restrained deformations may be neglected if the deformation capacity is sufficient and instability is excluded (ULS αcr checked). Kept for the stays (V6) and the abutment bearing anchorageproject assumption
Distance e from the abutment bearing axis to the carriageway joint (deck end)0.5mUsual preliminary design value for the joint and the bearings. Vertical displacement at the joint: v_bearing ∓ e θ_bearing (small rotations)design choice
Abutment bearingsancréDesign choice: anchored bearings at both abutments, which hold the vertical reaction in both directions and let the deck slide horizontally. The anchorage is designed for the largest ULS design tension (γG,inf on the favourable permanent load, traffic, braking and temperature on the unfavourable side), the bearing for the largest ULS design compression (γG,sup)design choice
Width b of each of the 2 carriageways for the lane layout: 5.0 m + 0.25 m of trafficable clearance in front of the central reserve barrier5.25; 5.25mProject assumption, most unfavourable reading of SIA 261:2020 Table 9 (which does not say where b is measured): b = 5.25 m < 5.4 m, hence 1 lane of 3.0 m and 2.25 m of remaining area per carriageway. Fixed central barrier: each carriageway divided separately, a single numbering (10.2.1.2, 10.2.1.3); lane 1 on one carriageway, lane 2 on the otherproject assumption
Application points of the braking force QBkx = 0 m or x = 280 m, in both directionsProject assumption: QBk applied at a deck end, at either abutment, in either direction, at carriageway level (box axis + v_top + surfacing). The abutment case gives the largest axial force in the span (of the order of QBk); sliding abutments: the whole force goes to the pylonproject assumption
Ernst iteration stop: max |ΔEeq| / Eeq10−9Converges in 2 iterations with the stays of this bridgedesign choice
Floor stress in the Ernst formula1MPaAvoids division by zero if a stay goes slackdesign choice

11 · Validation

Two implementations written separately, the same numbers

I had a second implementation written in Python (numpy) from the mechanical specification alone, without reading the JavaScript code: pont_ref.py. Both start from hypotheses.js. The script comparer.py compares every value, in output units, against two criteria: 0.5 % or 10−3 absolute, and the strict 10−6 relative criterion (with a floor of 10−9 times the group maximum for values that are zero by symmetry).

30,562 values in 357 groups pass both criteria. The worst relative gap in any group is 1.3 × 10−10; on the η, the largest absolute gap is 3.5 × 10−11. The Python reference covers all fifteen checks, V1 to V15, braking, temperature and ηt point by point. On two points it deliberately takes another route: the uniform temperature freely expands every element there (the JavaScript code only applies the elongation of the pylon below the deck, which is equivalent), and the maximum stress after locking (V14) is found by bisection and numerical integration instead of the closed form. All 17 of its check cases pass.

JavaScript / Python comparison summary (outils/comparer.py)
FamilyGroupsValuesWorst relative gap
Derived data (A, I, W, Ec, fcd, fpd, q, Q, QBk, P1, P2, σp, T2k…)42427e−16
Case 1: two-span continuous beam774e−12
Case 2: tuning gives a beam on rigid supports3501e−12
Case 3: tuning residuals331e−13
Cases 4 to 6: equilibrium, symmetry, linearity55pass/fail
Case 7: Maxwell-Betti reciprocity364e−11
Case 8: Ernst modulus5292e−12
Case 9: pylon cantilever365e−11
Cases 10 and 11: prestress alone, point loads363e−12
Tuning (Eeq, t, ΔL0, Δp, NG, NP, Nperm)101943e−12
Cases R1, R2, R3 (first order): displacements, N, M, σ, stays, reactions, pylon, end forces, carriageway joint639,6186e−11
States on screen (second order): deflection, head u, braking of the frame, η V1 to V15 and their locations241368e−12
Traffic envelopes, SLS (carriageway joint included)446,4404e−11
Traffic envelopes, ULS202,3881e−10
Governing tandem positions223,153identical
Braking: SLS and ULS envelopes, effects on the pylon and the deck192,2241e−10
Temperature: SLS and ULS envelopes, unit cases T1 and T2354,4222e−11
Second order: fixed axial forces, αcr, effect on a traffic case52026e−11
Checks V1 to V15 (η, demands, locations, statuses)161444e−11
SIA 262: ηt point by point, tensioning, creep141,4312e−11
Findings (deflections, abutment) and the no-tuning case7395e−11
Anchored abutment bearings: ULS Rd, Fd,anchorage, max compression, governing combinations4171e−11

I checked second order in three other ways. The Python reference computes αcr with a full eigenvalue decomposition (numpy), without iteration; it also recovers the Euler load of a pinned column to within 10−4 with the same geometric matrix. The JavaScript code checks that K + 0.999 αcr KG is positive definite and that K + 1.001 αcr KG no longer is, and that the moment at the end of each element equals the end moment of (k + kG) d.

Two implementations that agree rule out programming errors (sign, index, rotation, forgotten load). They do not protect against a shared modelling error, since they start from the same specification. That is the job of the analytical cases (continuous beam, three-moment equation, pylon cantilever, prestress alone, point loads), the global equilibrium and the orders of magnitude. They all pass, among the 301 checks of test-modele.mjs. The comparison shows the calculation is done right.

To rerun the checks: download modele.js, hypotheses.js, cadrage.js and the three scripts above, keeping the folders (structure3d/, structure3d/outils/, structure3d/outils/reference/), then, from structure3d/, with Node 18 and Python 3 with numpy:

node outils/test-modele.mjs
python3 outils/comparer.py --rapport tableau.md

12 · Outside the model

What the model does not compute

  • Linear elastic materials, uncracked section. Linearised second order, with the fixed axial forces of the combination; no large displacements, no initial pylon imperfections, no stiffness loss from pylon cracking or creep.
  • Plane model: transverse bending and the split between webs stay outside the model. The full section width is assumed effective.
  • Creep and shrinkage (redistribution between deck and stays over time), settlement, construction stages, vibrations: not computed. Comfort is only checked through the frequent deflection (V10).
  • Not checked: shear, design of the pylon sections to second order with imperfections, passive reinforcement.
  • Anchorages on the deck and pylon axes (eccentricities neglected), distributed load applied on whole 5 m elements in the envelopes, lump-sum prestress losses.

Known code effects, declared outside the model (HORS_MODELE list in hypotheses.js, also in the export):

  • Computed: T1k (concrete ±20 °C, stays ±30 °C, same direction) and the deck T2k (+9 °C / −3.25 °C). Outside the model: gradient in the mast (sun on one face), non-linear part T3 (not considered as a rule, 7.2.1), difference between the erection temperature and the site mean, 50 % increase for bearings and joints (7.2.6, movement at the abutments of about 4 to 6 cm). (SIA 261:2020, 7.2.1, 7.2.3, 7.2.6)
  • Dynamic factor 1.3 on axle loads within 3 m of a joint: local effect (abutment reaction, joint, slab), no effect on the global forces of the model. (SIA 261:2020, 10.3.4)
  • Transverse braking 0.25 QBk and out-of-plane effects: transverse bending of the pylon, outside the plane model. (SIA 261:2020, 10.2.5.4)
  • Cracking, increased requirements: checked on the reinforcement and bonded tendons (steel stress in the cracked section), outside the model. V3 and V4 are stricter design choices on the concrete. (SIA 262:2013, 4.4.2, Table 17, Figure 31)
  • Torsion from the eccentric lanes (central stay plane) and eccentricity of braking in the axis of lane 1 (10.2.4.3): torque of about 900 × 5.75 ≈ 5 MN·m (about 8 MN·m at ULS), carried by the box and the mast fixity, outside the plane model. (SIA 261:2020, 10.2.2.7, 10.2.4.3)
  • Section resistance (axial force and bending, reinforcement and tendons counted as resistance): not computed. V8 and V9 are simplified elastic criteria, design choices; only the values fcd, ηfc and ηt come from SIA 262. (SIA 262:2013, 4.3, 4.1.5.5.1)
  • Preliminary design: the stop of the 17 end tendons is idealised in one section (x = 80 m and x = 200 m), the staggering is to be studied in the detailed design. Anchorage and spreading zones per the system approval, outside the model. (SIA 262:2013, 4.1.5.1.7, 4.1.5.2.5)
  • Fatigue of stays and tendons: not checked. (SIA 261:2020, 10.4)
  • Wind: for a cable-stayed bridge, the SIA 261 rules apply only with expert support; not modelled. (SIA 261:2020, 6.1.2, 6.1.3)
  • Vehicle impact on the mast and earthquake: accidental situations, not modelled. (SIA 261:2020, 14.2 and chapter 16)

13 · Export

The full model, to rebuild it in SCIA

Both files hold the assumptions with their status, the nodes, elements, sections, stays (Eeq, pretension t and shortening ΔL0), supports, loads (braking and temperature included), the fixed second-order axial forces and the results of 3 first-order reference cases: R1 (tuned permanent state), R2 (R1 plus the tandem at 42 m, the rest image), R3 (R1, tandem at 70 m and full distributed load). The JSON adds the envelopes (traffic, braking, temperature); both files give the checks with the status of their criterion and the list of effects outside the model. Field names are in French; the CSV is UTF-8 with a BOM, separator “;”.

For SCIA: linear analysis, stays as bars with Eeq fixed per stay, tuning by pretension t (or ΔL0), Δp as an imposed strain ε0 = Δp / 20 m on the 2 pylon elements below the deck, sections by A and I, shear deformation switched off. End forces in each element’s local axes. A geometrically nonlinear SCIA analysis will differ from first order by about 10 % on the traffic effects, as described in chapter 08.

See the bridge on the home pageSee the other projects

Contact

Let's talk?